Search results for "Surgical mesh"

showing 10 items of 53 documents

Giant pseudocyst of the abdominal wall following incisional ventral hernia repair: an extremely rare clinical entity. Report of a case

2021

Il “gold standard” per il trattamento dei laparoceli è l’intervento chirurgico con impiego di protesi, nonostante questo approccio sia gravato da numerose complicanze post-operatorie; tra queste possiamo annoverare le pseudocisti giganti della parete addominale, tale evenienza risulta ancora molto rara e la sua eziopatogenesi riamane non chiara. In questo lavoro descriviamo il caso clinico di una paziente di 36 anni, diabetica ed obesa, precedentemente sottoposta a taglio cesareo e riparazione di laparocele con posizionamento di protesi in sede soprafasciale. La paziente si è presentata presso i nostri ambulatori per la comparsa di un gonfiore asintomatico a livello della fossa iliaca sinis…

AdultCystsRecurrenceAbdominal WallDiabetes MellitusHumansIncisional HerniaFemaleObesitySurgical MeshAbdominal Wall pathology Adult Cysts* / pathology Diabetes Mellitus Female Hernia Ventral* / surgeryHernia VentralHerniorrhaphy
researchProduct

Serum VEGF and b-FGF profiles after tension-free or conventional hernioplasty.

2005

Angiogenesis is strongly influenced by vascular endothelial growth factor (VEGF) and basic fibroblast growth factor (b-FGF), whose production is also regulated by interferon (IFN)-gamma and interleukin (IL)-10. The aim of this study was to evaluate the modifications of serum VEGF, b-FGF, IFN-gamma and IL-10 levels in patients with inguinal hernia undergoing hernioplasty with the Lichtenstein technique (LH) using polypropylene mesh or with Bassini open conventional inguinal hernia repair (BH). MATERIALS AND METHODS: Randomly, 16 patients underwent BH, and 16 were treated with the LH technique using polypropylene mesh. Blood samples were collected 24 h prior to surgery and then 6, 24, 48 and …

AdultMaleVascular Endothelial Growth Factor Amedicine.medical_specialtyAngiogenesisBasic fibroblast growth factorUrologyEnzyme-Linked Immunosorbent AssayHernia InguinalStatistics Nonparametricchemistry.chemical_compoundInterferon-gammaMedicineHumansIFN-γMeshAnalysis of Variancebusiness.industryInterleukinMiddle AgedSurgical Meshmedicine.diseaseVEGFSurgeryInterleukin-10Vascular endothelial growth factorInterleukin 10Inguinal herniachemistryHernioplastyIL-10SurgeryCytokine secretionFibroblast Growth Factor 2b-FGFbusinessAbdominal surgery
researchProduct

Impact of Heavy Polypropylene Mesh and Composite Light Polypropylene and Polyglactin 910 on the Inflammatory Response

2010

The aim of the study was to analyze the acute inflammatory response after implantation of a heavyweight mesh of polypropylene (PP) compared with a composite mesh of light PP and polyglactin 910 (PG) in patients undergoing inguinal hernioplasty. A total of 30 male patients with inguinal hernia were included in the study and divided into 2 groups (PP and PP-PG) according to the mesh used. Changes of leukocytes, cytokines, growth factors, and acute phase proteins were evaluated in the sera. Leukocytes and acute phase proteins were significantly increased postoperatively in both groups, and the values were slightly higher in the PP group. Cytokine levels were significantly increased postoperat…

AdultMaleVascular Endothelial Growth Factor Amedicine.medical_specialtymedicine.medical_treatmentInflammatory responseUrologyBiocompatible MaterialsHernia InguinalPolypropylenesProinflammatory cytokinechemistry.chemical_compoundTransforming Growth Factor betaHumansMedicineHerniaPolyglactin 910AgedInflammationPolypropyleneInterleukin-6business.industryPolyglactin 910Acute-phase proteinMiddle AgedSurgical Meshmedicine.diseaseSurgeryFibroblast Growth FactorsInterleukin 1 Receptor Antagonist ProteinInguinal herniaC-Reactive ProteinCytokinechemistrySurgerybusinessSurgical Innovation
researchProduct

A minor modification of Lichtenstein repair of primary inguinal hernia: postoperative discomfort evaluation.

2010

The aim of this study was to evaluate the usefulness of a modification of the Lichtenstein hernioplasty procedure by evaluating its impact on postoperative discomfort. From December 1999 to May 2006, the Lichtenstein inguinal hernioplasty was performed in 406 patients with noncomplicated unilateral inguinal hernia. During reconstruction, the mesh was fixed to the inguinal canal floor without stitching its upper margin to the internal oblique muscle. Control of postoperative pain proved to be satisfactory; 72 hours after surgery, 26.1 per cent of patients no longer felt any pain, whereas 54.4 per cent had slight pain without the need for painkillers; on Day 7, 92.8 per cent felt no pain at …

AdultMalemedicine.medical_specialtyAdolescentPostoperative paininguinal hernia repair Lichtenstein postoperative discomfortHernia InguinalQuality of lifemedicineHumansHerniaInguinal hernioplastyAgedPain MeasurementAged 80 and overPain PostoperativeChi-Square Distributionbusiness.industryChronic painRecovery of FunctionGeneral MedicineMiddle AgedSurgical Meshmedicine.diseaseInguinal canalSurgerySettore MED/18 - Chirurgia GeneraleInguinal herniaTreatment OutcomeSurgical meshmedicine.anatomical_structureAnesthesiaFemalebusiness
researchProduct

Modified fixation free plug technique using a new 3D multilamellar implant for inguinal hernia repair: a retrospective study of a single operator cas…

2013

Aim: Implant fixation, mesh shrinkage and poor quality of tissue ingrowth are unresolved issues in modern hernia repair. Many complications reported in the literature such as bleeding, nerve entrapment, hematoma, pain, discomfort, and testicular complications, are considered to be a direct results of implant fixation. This article describes the outcomes of a procedure carried out using a handcrafted implant that addresses the issues consequent to point fixation. Methods: This was a retrospective study on the short, medium and long-term results of placing a-modified, fixation free three-dimensional polypropylene implant in 61 patients who underwent inguinal hernia repair using a novel delive…

AdultMalemedicine.medical_specialtyHerniaAdolescentmedicine.medical_treatmentprostheses and implantOperative TimeHernia InguinalPolypropylenesProsthesis DesignFixation (surgical)HematomaPostoperative ComplicationsRetrospective Studiemedicineprosthesis fixation.HumansHerniaHerniorrhaphyAgedRetrospective StudiesAged 80 and overPain Postoperativebusiness.industryHernia; Herniorrhaphy; Inguinal; Prostheses and implants; Prosthesis fixation; Adolescent; Adult; Aged; Aged 80 and over; Female; Hernia Inguinal; Herniorrhaphy; Humans; Male; Middle Aged; Operative Time; Pain Postoperative; Polypropylenes; Postoperative Complications; Prosthesis Design; Retrospective Studies; Treatment Outcome; Surgical Mesh; Surgery; Medicine (all)Medicine (all)Chronic painMiddle AgedSurgical Meshmedicine.diseaseHernia repairSurgeryInguinal herniaSettore MED/18 - Chirurgia GeneraleSurgical meshTreatment OutcomeinguinalSurgeryFemaleImplantPostoperative ComplicationbusinessProsthesis fixationPolypropylenehernia; inguinal; herniorrhaphy; prostheses and implants; prosthesis fixation.HumanHernia : the journal of hernias and abdominal wall surgery
researchProduct

New mesh shape and improved implantation procedure to simplify and standardize open ventral hernia repair: a preliminary report.

2010

Introduction Issues in ventral hernia repair are represented by the need for mesh fixation and how to assure a sufficient mesh overlap of the defect. Aiming to resolve these problems, this study describes a modified technique for ventral and incisional hernia repair based upon a newly developed mesh with a special design. This new type of implant allows broader coverage of the abdominal wall and results in tension- and fixation-free repair. Materials and methods A unique geometrically shaped mesh consisting of a large central body and radiating arms was used to repair ventral or incisional hernia. The mesh was intended not to be point-fixated. The friction of the straps passing through the …

AdultMalemedicine.medical_specialtyHerniaFrictionIncisional herniaAbdominal wallProsthesis ImplantationHematomaPreliminary reportProstheseRecurrencemedicineHumansSurgical Wound InfectionHerniaHerniorrhaphyFixation (histology)AgedSurgical fixation deviceVentral hernia repairbusiness.industryAbdominal WallImplantMiddle AgedSurgical Meshmedicine.diseaseHernia VentralSurgerySettore MED/18 - Chirurgia Generalemedicine.anatomical_structureSeromaVentralSurgeryFemaleImplantbusinessFollow-Up StudiesHernia : the journal of hernias and abdominal wall surgery
researchProduct

Tentacle-shaped mesh for fixation-free repair of umbilical hernias

2019

Purpose: Mesh fixation and broad overlap represent an open issue in umbilical hernia repair. A proprietary-designed implant with tentacle straps at its boundary has been developed to ensure a suture-free repair and a broader coverage of the abdominal wall. The study describes the results of umbilical hernia procedures carried out with the tentacle-shaped implant and the related surgical technique. Methods: A proprietary tentacle-shaped flat mesh having a central body with integrated radiating arms at its edge was used to repair large umbilical hernias in 62 patients. The implant was placed in preperitoneal sublay. The friction of the straps, crossing the abdominal wall thanks to a special n…

AdultMalemedicine.medical_specialtyHerniaHow-I-Do-Itmedicine.medical_treatmentNavelProsthesisProsthesis ImplantationAbdominal wallFixation freeRecurrenceUmbilicalmedicineHumansHerniaFreexationFriction forceHerniorrhaphyAgedUmbilicusTentacle meshbusiness.industryAbdominal WallSuture TechniquesProstheses and ImplantsMiddle AgedSurgical Meshmedicine.diseaseHernia repairUmbilical herniaSurgerySurgical meshmedicine.anatomical_structureHernia repairFemaleSurgeryImplantbusinessHernia UmbilicalHernia
researchProduct

PTFE mesh in renal allograft compartment syndrome.

2006

We report a case of anuria in a 42-year-old female kidney transplant patient that occurred secondary to extrinsic compression from a large kidney being placed extraperitoneally in a small iliac fossa. Prompt reexploration in the immediate postoperative period resulted in salvage of the graft with restoration of kidney function. The abdominal wall was reconstructed using prosthetic mesh, which decreased the compartment pressure within the iliac fossa sufficiently to allow the renal vein patency and the kidney perfusion. We think that this tension-free surgical technique should be applied in those cases in which the retroperitoneal space is less than the size of the kidney to avoid renal allo…

AdultMalemedicine.medical_specialtyIncisional herniaIliac fossaAnuriaCompartment SyndromesRenal DialysismedicineRetroperitoneal spaceHumansTransplantation HomologousPolytetrafluoroethyleneKidney transplantationTransplantationKidneybusiness.industrySurgical Meshmedicine.diseaseKidney TransplantationSurgerymedicine.anatomical_structureSurgical meshSurgeryAnuriaRenal veinmedicine.symptombusinessTransplantation proceedings
researchProduct

Acute inflammatory response in the subcutaneous versus periprosthethic space after incisional hernia repair: an original article.

2014

BACKGROUND: The acute inflammatory response following mesh implantation has been often evaluated in vitro and in animal models. The aim of this study was to evaluate the acute inflammatory response near the prosthesis in human by analysing some inflammatory indicators.METHODS: We used a cohort of twelve male patients affected by midline incisional hernia, who were admitted for surgical mesh repair. A suction drain was placed between the mesh and rectal muscles whereas, the other one was placed between the subcutaneous tissue and the oblique external sheath. The acute inflammatory response was analyzed by measuring the production of interleukin [IL]-1, IL-10, IL-1ra, C-Reactive Protein (CRP)…

AdultMalemedicine.medical_specialtyIncisional herniamedicine.medical_treatmentAcute Disease; Adult; Biomarkers; C-Reactive Protein; Cytokines; Follow-Up Studies; Hernia Ventral; Herniorrhaphy; Humans; Inflammation; Male; Middle Aged; Surgical Mesh; Postoperative Complications; Medicine (all)InflammationProsthesisProsthesisFollow-Up StudiePostoperative ComplicationsDrain fluidmedicineHumansCytokineHerniorrhaphyInflammationbiologybusiness.industryMedicine (all)C-reactive proteinAlbuminInflammatory responseGeneral MedicineBiomarkerMiddle AgedSurgical Meshmedicine.diseaseHernia repairHernia VentralSurgerySettore MED/18 - Chirurgia GeneraleSurgical meshmedicine.anatomical_structureC-Reactive ProteinAcute Diseasebiology.proteinCytokinesHernia repairSurgeryPostoperative Complicationmedicine.symptombusinessBiomarkersSubcutaneous tissueHumanFollow-Up StudiesResearch ArticleBMC surgery
researchProduct

Intraperitoneal Onlay Mesh Technique for Spigelian Hernia in an Outpatient and Short-Stay Surgery Unit: What's New in Intraperitoneal Meshes?

2018

Spigelian hernia (SH) is a rare entity, but its surgical treatment is essential because of its high complication risk. Laparoscopic approaches have become the option in elective surgery because it has less morbidity and requires a shorter stay. Several laparoscopic techniques have been employed, but there is no gold standard technique for this kind of hernia. We report, in this study, our experience with intraperitoneal onlay mesh (IPOM) repair.Fifteen patients underwent elective surgery for SH between 2008 and 2015 in a Short-Stay Surgical Unit. Laparoscopic IPOM technique was performed in all patients. The technique, epidemiological data, operative findings, hospital stay, morbidity, and …

AdultMalemedicine.medical_specialtyOperative Time030230 surgeryAmbulatory Care Facilities03 medical and health sciences0302 clinical medicineSpigelian herniaMedicineHumansSurgical treatmentHerniorrhaphyAgedRetrospective Studiesbusiness.industryRare entityLength of StayMiddle AgedSurgical Meshmedicine.diseaseShort stay surgeryHernia VentralSurgeryTreatment Outcome030220 oncology & carcinogenesisSurgeryFemaleLaparoscopyComplicationbusinessJournal of laparoendoscopicadvanced surgical techniques. Part A
researchProduct